Description
Ideal for troubleshooting and preventative maintenance, this insulation multimeter comes in a compact, handheld design, and features True RMS capabilities. Additionally, this tool is compatible with the Fluke Connect app, which allows the user to see and share measurement results wirelessly with their smartphone or tablet.
PI/DAR timed ratio tests (1587 FC only)
Live circuit detection prevents insulation test if voltage > 30 V is detected for added user protection
VFD low-pass filter for accurate motor drive measurements (1587 FC only)
Auto-discharge of capacitive voltage for added user protection
Insulation test (1587 FC: 0.01 MΩ to 2 GΩ) (1577: 0.1 MΩ to 600 MΩ)
Insulation test voltages (1587 FC: 50 V, 100 V, 250 V, 500 V, 1000 V),(1577: 500 V, 1000 V) for many applications
AC/DC voltage, DC millivolts, AC/DC milliamps, Resistance (Ω), Continuity
Capacitance, diode test, temperature, Min/Max, frequency (Hz)(1587 FC only)
Auto power off to save battery power
CAT III 1000 V, CAT IV 600 V measurement category
Rugged, utility hard case allows you to bring everything you need for the job
Large display with backlight
Specifications:
Voltage DC
Maximum Voltage: 1000V
Maximum Resolution: 0.001V
Accuracy: ±(0.09%+2)
Voltage AC
Maximum Voltage: 1000V
Maximum Resolution: 0.1 mV
Accuracy: ±(2%+3)
Current DC
Maximum Amps: 400mA
Maximum Resolution: 0.01 mA
Amps Accuracy: ±(0.2%+2)
Current AC
Maximum Amps: 400mA
Maximum Resolution: 0.01 mA
Amps Accuracy: ±(1.5%+2)*
Resistance
Maximum Resistance: 50 MΩ
Maximum Resolution: 0.1Ω
Accuracy: ±(0.9%+2)
Insulation Test
Minimum Test Current @ 1kΩ/V:1mA
Test Voltages: 1577:500, 1000V
Maximum Resistance per Test Voltage: 50V; 100V; 250V; 500V; 1000V: 600 MΩ
Maximum Resolution per Test Voltage: 50V: 0.01 MΩ; 100V: 0.01 MΩ; 250V: 0.1 MΩ; 500V: 0.1 MΩ; 1000V: 0.1 MΩ
Accuracy per Test Voltage: 50V: ±(3% + 5); 100V: ±(3% + 5); 250V: ±(1.5% + 5)
General Specifications
Dimensions: 203x100x50mm (with holster)
Weight: 624g
Battery Life: Meter use: 1000 hours; Insulation test use: Meter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off.